EP5520/EP5520T vSignage cut-in S/N

    Product Cut in S/N EP5520T phase-in from UVE173100001 EP5520 phase-in from T91173300001

Where to apply Sigange Manager and vSigange Weather API key

Apply web URL https://developer.worldweatheronline.com/api/pricing.aspx 

The image is distorted from NMP-302w HDMI out, how can I do?

You can refer below steps to check the issue. 1. To reset the NMP-302w. 2. To replace the HDMI(extension) cable. If above steps can't solve the issue, it will be NMP-302w mainboard issue, you need to replace NMP-302w.

How to set up video wall in daisy chain?

Here’re major steps to set up video wall in portrait position for your reference. 1. Set up  monitor ID in OSD menu as 1~4 prior to mounting monitors.   2. Connect  IR sensor cable to monitor 1.   3. Connect  the PC to monitor 1 with DP cable firstly for easy setup & adjustment  afterwards.   4. Mounting  monitor 1/2/3/4 in portrait p...

How to check whether vSignage can sync with others players and see the campaign?

If you are unable to sync the contents, there may be a connection issue.    To verify if the admin is sync with the player, there is a JSON API in vSignage. 1. First make sure your windows firewall setting has allow vSigange to access. 2. Please use this API to check if source player see any other players and campaign. Open the Chrome br...

How to check CDX series , videowall, model RS232 daisy chain working correctly

1. Is it correct of RS232 daisy chain cable ? 2. In OSD menu, General settings -> Eco mode please set to Normal. (If set to Low power standby, the unit can power OFF but can’t power ON) 3. The RS232 daisy chain cable is 2.4mm – 2.4mm

How to make sure the CDE4302 can meet the 350 nits brightness

According EE class A requirement we need to set default from 300-350 nits to 210-245 nits , but it may cause CDE4302 has lower brightness.  Here are the testing equipment and method for testing the 350 nits spec. 1. Using KONICAMINOLTA CA-210 or CA-310 pattern generator and color meter to get the following testing result. 2. Increas...

What are the communication settings to control IFP via RS232 and LAN commands?

RS232 Communication Setting  - Baud Rate Select: 9600bps (fixed) - Data bits: 8 bits (fixed) - Parity: None (fixed) - Stop Bits: 1(fixed)   LAN Communication Setting - Type: Ethernet  - Protocol: TCP/IP - Port: 5000 (fixed) - Cross subnet: No - Logon Credentials: No

What are the requirements or limitation on the using cables of Videowall?

Support HDMI Ver. 1.4b DVI cable can't exceed 5M, otherwise, a DVI extender is required HDMI cable can't exceed 5M, otherwise, a HDMI extender is required LAN Cable can't be used to carry video signal directly Signal cable for each display should be separated from each other, twists cables together is not allowed Device for signal transmi...

Does CDE4302 have a Clone feature?

Yes, CDE4302 / CDE4803 / CDE4803-H/CDE 5520 have a clone feature and following is clone SOP setting in the OSD:  CDE4302/4803/4803-H/5502 OSD Clone SOP  1.     Plug USB storage on USB port 2.     Set the item in OSD menu what parameter you need. 3.     Press MENU 1 9 9 9 OK on remote control to entry factory menu 4.     In factory m...

Commercial Display Support

General InquiriesContact Us